You can download Wilcom EmbroideryStudio 12.0.0075 from our software library for free. Our antivirus analysis shows that this download is virus free. Wilcom EmbroideryStudio is suitable for 32-bit versions of Windows XP/Vista/7/8. Desloadr.exe and ES.EXE are the most common filenames for this program's. ![Wilcom software download free Wilcom software download free](/uploads/1/2/5/0/125045522/303642202.jpg)
![Wilcom software download free Wilcom software download free](/uploads/1/2/5/0/125045522/303642202.jpg)
Fs-n10 series, User's manual. Read online or download PDF. KEYENCE FS-N10 Series User Manual. Models in FT series by KEYENCE Canada: Amplifier, Cable, Other option, Sensor head. Tcm:47-751873-64 To use all available functions on this website, JavaScript must be enabled in your browser. IV-G10, For IV-G, Sensor Amplifier, Main unit in IV series by KEYENCE India. Tcm:-64 To use all available functions on this website, JavaScript must be enabled in your browser.
- Keyence Ft Series Manual Instructions
- Keyence Ft Series Manual Download
- Keyence Ft Series Manual Download
- Keyence Ft Series Manual Free
LR-ZB*N/P Series_IM_E
CMOS Laser Sensor
246 Instruction Manuals and User Guides for KEYENCE online. Read online or download owner's manuals and user guides for KEYENCE. Models in FT series by KEYENCE America: Amplifier, Cable, Optional parts, Sensor head. Tcm:26-277102-64 To use all available functions on this website, JavaScript must be enabled in your browser. Razer kraken usb software. Accessories Keyence CV-301 Series Instruction Manual. Compact color vision system (86 pages) Accessories Keyence EX-305V Instruction Manual. Ex-v series high-speed.
F
Instruction Manual
Read this manual before using the product in order to achieve maximum performance.
Keep this manual in a safe place after reading it so that it can be used at any time.
The following symbols alert you to important messages.
*The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in
accordance with the requirements of Laser Notice No.50.
Identification Label
U.S. affix the Certification and
the package of this product as
(Affix this label in a location that is not splashed with oils or chemicals.)
This product is an UL/C-UL Listed product.
•UL File No. E301717/Category NRKH. NRKH7/Enclosure Type 1 (UL50)
Be sure to consider the following specifications when using this product as a UL/CUL
•Use a power supply with Class 2 output defined in NFPA70 (NEC: National Electrical
•Power supply/ Control input/ Control output shall be connected to a single Class 2
•Install the product at the ambient temperature 45°C or below when using with following
optional cable. (OP-73864, OP-73865, OP-87396, OP-85499, OP-85500,OP-85497,
CE Marking
KEYENCE Corporation has confirmed that this product complies with the essential
requirements of the applicable EC Directive, based on the following specifications.
Be sure to consider the following specifications when using this product in a member state
zEMC Directive (2004/108/EC)
•Applicable standardEMI: 60947-5-2, Class A/EMS: 60947-5-2
These specifications do not give any guarantee that the end-product with this product
incorporated complies with the essential requirements of EMC Directive. The manufacturer
of the end-product is solely responsible for the compliance on the end-product itself
*1Display reading used as a guide for the detecting distance. When the setting value is
tuned, the readout shifts. When the value exceeds “-99”, “-FF” is displayed.
*2The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in
accordance with the requirements of Laser Notice No.50.
M8 connector (3-pin) type does not include the external input function.
NPN type (LR-ZB*N)
It indicates a hazardous situation which, if not avoided, could result in
It indicates a situation which, if not avoided, could result in product
Safety Information for LR-ZB Series
•This product is only intended to detect object(s). Do not use this
product for the purpose to protect a human body or part of a human
•This product is not intended for use as an explosion-proof product.
Do not use this product in a hazardous location and/or potentially
•This product uses DC power.The product may explode or burn if an
•Do not wire the cable along with power lines or high-tension lines,
as the sensor may malfunction or be damaged due to noise.
•When using a commercially available switching regulator, ground
•Do not disassemble this product. Laser emission from this product
is not automatically stopped when it is disassembled.
•Use with an over current protection device which is rated 30 V or
Safety Precautions on Laser Product
•This product uses a semiconductor laser for the light source.
•Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation
•Follow the instructions mentioned in this manual. Otherwise, injury
•Laser emission from this product is not automatically stopped
when it is disassembled.Do not disassemble this product.
Wavelength/Output660 nm/145 μW
*
IEC 60825-1Class 1 laser product
L’utilisation des commandes ou réglages ou l’exécution des
procédures autres que celles spécifiées dans les présentes exigences
peuvent être la cause d’une exposition à un rayonnement dangereux.
Identification Label
Specifications
AppearanceRectangular
2 m cableLR-ZB100NLR-ZB250N
LR-ZB100CNLR-ZB250CN
2 m cableLR-ZB100PLR-ZB250P
LR-ZB100CPLR-ZB250CP
LR-ZB100C3PLR-ZB250C3P
35 to 100 mm (650 to 0)
35 to 250 mm (215 to 0)
Standard detection deviation
50 to 100 mm : 3 mm
180 to 250 mm : 25 mm
Spot diameter2 X 1 mm at 100 mm2.4 X 1.2 mm at 250 mm
TypeRed laser (660 nm)
Class 1 laser product
*2
Indicator
output indicator (yellow),
DATUM indicator (orange), 1 spot indicator (green)
Power voltage
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
450 mW or less (18 mA or less at 24 V, 34 mA or less at 12V)
LR-ZB*N: NPN Open collector
Applied voltage 30 VDC or less,
Residual voltage 1.2 V or less at 10 mA or less,
Protection circuit
Protection against reverse power connection, output overcurrent,
Output operationLight-ON / Dark-ON selectable
*3
Input time calibration: 35 ms or more ON, 35 ms or more OFF
![Manual Manual](/uploads/1/2/5/0/125045522/125482777.jpg)
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less
IP68 (IEC60529)/IP69K (DIN40050-9)/
Ambient light
Incandescent lamp:
Sunlight: 8000 lx or less
2000 lx or less
Ambient temperature-10 to +50°C
Keyence Ft Series Manual Instructions
Ambient humidity35 to 85%RH
2
Vibration resistance
10 to 55 Hz Double amplitude 1.5 mm in the X, Y, Z
Insulating resistance20 MΩ or more (500 VDC)
Material
Lens cover: PMMA with scratch-resistant coating,
Weight
M8 connector type: Approx. 55 g
source
PLC, etc.
Keyence Ft Series Manual Download
Load
protection circuit
0 V
Blue/3
Black/4
Keyence Ft Series Manual Download
![Keyence Keyence](/uploads/1/2/5/0/125045522/701358321.jpg)
2
4
Sensor main circuit
Overcurrent
10 to 30 VDC
Brown/1
White/2*
1
3
4
M8 connector (3-pin) type
96M11812